This is an instructional guide on how to reset the sensors in a Newport system.
2nd Gen Newport Pack
System Reset:
Follow grey wires from each end of the heater tube until they connect to one plug at JP9. Unplug heater sensor plug from board for approximately 30 seconds then plug back in.
System Reset:
- Turn spa off
- Move left dipswitch (labelled #2) down for system reset
- Turn spa on (screen will be blank) and wait 30 seconds
- Turn spa off
- Move left dipswitch back up
- Turn spa on
Follow grey wires from each end of the heater tube until they connect to one plug at JP9. Unplug heater sensor plug from board for approximately 30 seconds then plug back in.
1st Gen Newport Pack (has daughterboard on left side)
System Reset:
Follow grey wires from each end of the heater tube until they connect to one plug at JP9. Unplug heater sensor plug from board for approximately 30 seconds then plug back in.
System Reset:
- Turn spa off
- Move dipswitch #12 up for system reset
- Turn spa on (screen will be blank) and wait 30 seconds
- Turn spa off
- Move dipswitch #12 back down
- Turn spa on
Follow grey wires from each end of the heater tube until they connect to one plug at JP9. Unplug heater sensor plug from board for approximately 30 seconds then plug back in.